Electrical Final Standards Checklist

Leer en Español
Read in English

Section 1: Final Installation & Commissioning Checklist

  • Devices installed neatly and aligned: All switches, receptacles, and cover plates
    installed straight, level, and flush with wall surfaces.
  • Lighting fixtures installed correctly: Fixtures mounted securely, centered, and
    oriented per design with no damage or missing parts.
  • All bulbs and trims installed: Verify all specified lamps and trims are installed,
    functional, and matching design intent.
  • Panel labeling completed: All circuits clearly and permanently labeled with accurate
    room and load descriptions.
  • Breaker labeling legible: Panel schedule corresponds with installed circuits and is
    easy to read.
  • Grounding and bonding verified: All metallic systems bonded per code; grounding
    conductors connected to panel and water line as required.
  • Arc-fault and GFCI devices tested: All required circuits protected and tested for
    proper trip and reset function.
  • Smoke and CO detectors installed: All detectors installed per code locations, powered,
    and interconnected.
  • Exterior lighting and outlets tested: All outdoor fixtures and GFCI receptacles
    operational and weatherproof covers installed.
  • Receptacles tested for polarity and voltage: Each receptacle tested for correct wiring,
    grounding, and voltage within acceptable range.
  • Switches and dimmers tested: All control devices function correctly, dim smoothly,
    and control intended loads.
  • Ceiling fans balanced and tested: Fans operate quietly, on all speeds, and without
    noticeable wobble.
  • Appliance circuits verified: Dedicated circuits installed and energized for required
    appliances (oven, range, microwave, etc.).
  • Lighting controls programmed: Smart switches, timers, and scenes configured to
    homeowner preferences if applicable.
  • Doorbell and low-voltage systems tested: Verify chime, transformers, and any
    control wiring (security, data, A/V) are operational.
  • Electrical trim complete: No exposed wiring; blank plates installed on all unused
    openings.
  • Electrical devices clean and undamaged: No paint, dust, or scratches on trim or
    fixtures.
  • Panel cover installed securely: Deadfront properly fitted, with all breakers seated and
    labeling visible.
  • Final inspection passed: System approved by electrical inspector and ready for
    occupancy.
  • Work area cleaned: All debris removed, fixtures wiped down, and site left in clean
    condition.